DESCRIPTION
The pump is mainly used in machines, small and medium-sized enterprises that do not require more than 75 points respectively and equipped with dispensers of the type F (resistance system).
OPERATION
The pump is operated manually and it works as an accumulator. By pressing on the lever compresses a spring filling a cylinder with an amount of oil by default. When you release the lever, a piston pushed by the spring force of the circulation of the oil in the ducts. The oil volume is accurately measured regardless of viscosity.
FEATURES
Flow :......... adjustable for 6 or 18 cm3 /stroke (adjustment screw and lock nut on the tank).
Pressure :................................................................................................................................. 5 bar max.
Depósito:........................................................................................................................................ 1 liter
Filter: ................................................................. Mounted in the suction filtration to 40 microns.
Must be inspected regularly and replaced once a year.
The viscosity of the oil at the operating temperature should lie between 30 and 1500 cSt.