The check valve allows free flow from the directional valve (2) pressure (1) while a discharge valve direct piloted controls the flow rate of 1 to 2. The display (3) lower the effective adaptation of the discharge valve to a value determined by the ratio of riding. The backpressure in 2 does not affect the valve setting because the spring has an atmospheric reference.